https://issues.apache.org/jira/browse/IGNITE-11299?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16766114#comment-16766114
 ] 

Ilya Kasnacheev commented on IGNITE-11299:
------------------------------------------

Yes, it seem to fix Windows under Java 11 too.

I expect that under Windows it will either generate 'write available' or 'read 
available' socket events but not 'write and read available'. So until you 
unregister OP_WRITE you will not be getting read events even if reading is 
actually available.

> During SSL Handshake GridNioServer.processWrite is invoked constantly
> ---------------------------------------------------------------------
>
>                 Key: IGNITE-11299
>                 URL: https://issues.apache.org/jira/browse/IGNITE-11299
>             Project: Ignite
>          Issue Type: Bug
>          Components: general
>    Affects Versions: 2.7
>            Reporter: Ilya Kasnacheev
>            Priority: Major
>




--
This message was sent by Atlassian JIRA