Ilya Kasnacheev commented on IGNITE-11299:
------------------------------------------
Yes, it seem to fix Windows under Java 11 too.
I expect that under Windows it will either generate 'write available' or 'read
available' socket events but not 'write and read available'. So until you
unregister OP_WRITE you will not be getting read events even if reading is
actually available.
> During SSL Handshake GridNioServer.processWrite is invoked constantly
> ---------------------------------------------------------------------
>