Vyacheslav Koptilin created IGNITE-11775:
--------------------------------------------

             Summary: IgnitePdsWithTtlTest is flaky
                 Key: IGNITE-11775
                 URL: https://issues.apache.org/jira/browse/IGNITE-11775
             Project: Ignite
          Issue Type: Bug
    Affects Versions: 2.7
            Reporter: Vyacheslav Koptilin
            Assignee: Vyacheslav Koptilin
             Fix For: 2.8


It seems the reason for test failure is the fact that TTL manager cannot clean 
up all entries because of TTL throttling (see {{GridCacheTtlManager#expire}} 
and {{GridCacheOffheapManager.GridCacheDataStore#purgeExpired}}). It does not 
seem a bug/problem, it just required to set the 
{{IgniteSystemProperties.IGNITE_UNWIND_THROTTLING_TIMEOUT}} to a smaller value.



--