https://issues.apache.org/jira/browse/KUDU-3341?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

YifanZhang updated KUDU-3341:
-----------------------------
    Summary: Catalog Manager should stop retrying DeleteTablet when receive 
WRONG_SERVER_UUID error  (was: Catalog Manager should stop retrying 
DeleteTablet when receive WRONG_UUID_ERROR)

> Catalog Manager should stop retrying DeleteTablet when receive 
> WRONG_SERVER_UUID error
> --------------------------------------------------------------------------------------
>
>                 Key: KUDU-3341
>                 URL: https://issues.apache.org/jira/browse/KUDU-3341
>             Project: Kudu
>          Issue Type: Improvement
>          Components: master
>            Reporter: YifanZhang
>            Priority: Minor
>
> Sometimes a tablet server could be shutdown because of detected disk 
> failures, and this server would be re-added to the cluster with all data 
> cleared.
> Replicas could be replicated after  
> {{\-\-follower_unavailable_considered_failed_sec}} seconds. And then master 
> send DeleteTablet RPCs to this tserver, but receive either a RPC 
> failure(tserver was shutdown) or a WRONG_SERVER_UUID error(tserver started 
> with a new uuid), and keep retrying to delete tablets after 
> {{{}--unresponsive_ts_rpc_timeout_ms{}}}(default 1 hour).
> It's not so necessary to retry when receive WRONG_SERVER_UUID errors, because 
> the server uuid could only be corrected by restarting the tablet server, at 
> that time full tablet reports would sent to master and outdated replicas 
> could be deleted finally.



--
This message was sent by Atlassian Jira
(v8.20.1#820001)

Reply via email to