https://issues.apache.org/jira/browse/KUDU-3464?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Marton Greber updated KUDU-3464:
--------------------------------
Labels: client python (was: client)
> Failed mini-cluster creation leaves chronyd open in Python test infra
> ---------------------------------------------------------------------
>
> Key: KUDU-3464
> URL: https://issues.apache.org/jira/browse/KUDU-3464
> Project: Kudu
> Issue Type: Bug
> Reporter: Marton Greber
> Priority: Minor
> Labels: client, python
>
> *Description:*
> While working on adding extra startup flag support in the Python test infra I
> was tinkering with adding negative tests. One example, when a wrong flag name
> is specified in a test class.
> {code:python}
> class TestKuduTestStartupFlagsMasterWrongFlagName(KuduTestBase,
> CompatUnitTest):
> @classmethod
> def setUpClass(self):
> extra_master_flags=[("non_existent_flag","1")]
> extra_tserver_flags=[("tablet_apply_pool_overload_threshold_ms", "1")]
> error_msg = 'RUNTIME_ERROR'
> with self.assertRaisesRegex(self, Exception, error_msg):
> super(TestKuduTestStartupFlagsMasterWrongFlagName, self)\
> .setUpClass(extra_master_flags, extra_tserver_flags)
> def test_startup_flags_master_wrong_flag_name(self):
> pass
> class TestKuduTestStartupFlagsTserverWrongFlagName(KuduTestBase,
> CompatUnitTest):
> @classmethod
> def setUpClass(self):
> extra_master_flags=[("check_expired_table_interval_seconds","1")]
> extra_tserver_flags=[("non_existent_flag","1")]
> error_msg = 'RUNTIME_ERROR'
> with self.assertRaisesRegex(self, Exception, error_msg):
> super(TestKuduTestStartupFlagsTserverWrongFlagName, self)\
> .setUpClass(extra_master_flags, extra_tserver_flags)
> def test_startup_flags_tserver_wrong_flag_name(self):
> pass
> {code}
> By themselves, these test run fine. Running them after each other results in
> the following error:
> {code:bash}
> 2023-03-22T14:48:01Z Fatal error : Another chronyd may already be running
> (pid=377244), check /tmp/kudutest-0/minicluster-data/chrony.0/chronyd.pid
> Could not open connection to daemon
> {code}
> It times out with the above error, when the control flow reaches the second
> test:
> {code:python}
> _ ERROR at setup of
> TestKuduTestStartupFlagsTserverWrongFlagName.test_startup_flags_tserver_wrong_flag_name
> _
> Exception: Error in response: {'code': 'TIMED_OUT', 'message': 'failed to
> start NTP server 0: failed to contact chronyd in 1.000s'}
> During handling of the above exception, another exception occurred:
> self = <class
> 'kudu.tests.test_common.TestKuduTestStartupFlagsTserverWrongFlagName'>
> @classmethod
> def setUpClass(self):
> extra_master_flags=[("check_expired_table_interval_seconds","1")]
> extra_tserver_flags=[("non_existent_flag","1")]
> error_msg = 'RUNTIME_ERROR'
> with self.assertRaisesRegex(self, Exception, error_msg):
> super(TestKuduTestStartupFlagsTserverWrongFlagName, self)\
> > .setUpClass(extra_master_flags, extra_tserver_flags)
> E TypeError: _formatMessage() missing 1 required positional
> argument: 'standardMsg'
> kudu/tests/test_common.py:82: TypeError
> {code}
> I suspect that when the first cluster creation fails, chronyd is not properly
> disposed of.
> (After quitting the test execution, the referred /tmp/kudutest-0 location is
> properly cleaned up.)
> *Consequences:*
> If developers writing Python tests mess up a flag name, or value for more
> than once in the code they get "Could not open connection to daemon" errors.
> (which is not really helpful at first)
> However for properly written test code this bug has no negative effect.
--
This message was sent by Atlassian Jira
(v8.20.10#820010)