https://issues.apache.org/jira/browse/KUDU-3749?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Gabriella Lotz updated KUDU-3749:
---------------------------------
    Description: 
ksck, auto_rebalancer, and PartitionKey::DebugString() hex‑encode range/hash 
keys by streaming raw bytes into ostringstream. If char is signed and the range 
key contains bytes ≥ 0x80, the current 
static_cast<uint16_t>(range_key_begin[i]) will sign‑extend, producing incorrect 
hex output (e.g., ff becomes ffff). This is a correctness issue in the encoded 
representation and can lead to inconsistent range tags between components.

Proposed fix: Use an unsigned byte cast before widening in both places, e.g.:

static_cast<uint16_t>(static_cast<uint8_t>(range_key_begin[i]))
or an equivalent helper to ensure 0–255 semantics.

Locations:

src/kudu/tools/ksck.cc (range_key_begin formatting)
src/kudu/master/auto_rebalancer.cc (range_key_begin formatting)
src/kudu/common/partition.cc (PartitionKey::DebugString())

  was:
Both ksck and auto_rebalancer hex‑encode range_key_begin by streaming raw bytes 
into ostringstream. If char is signed and the range key contains bytes ≥ 0x80, 
the current static_cast<uint16_t>(range_key_begin[i]) will sign‑extend, 
producing incorrect hex output (e.g., ff becomes ffff). This is a correctness 
issue in the encoded representation and can lead to inconsistent range tags 
between components.

Proposed fix: Use an unsigned byte cast before widening in both places, e.g.:

static_cast<uint16_t>(static_cast<uint8_t>(range_key_begin[i]))
or an equivalent helper to ensure 0–255 semantics.

Locations:

src/kudu/tools/ksck.cc (range_key_begin formatting)
src/kudu/master/auto_rebalancer.cc (range_key_begin formatting)


> Fix range_key_begin hex encoding to avoid signed-char sign extension
> --------------------------------------------------------------------
>
>                 Key: KUDU-3749
>                 URL: https://issues.apache.org/jira/browse/KUDU-3749
>             Project: Kudu
>          Issue Type: Bug
>            Reporter: Gabriella Lotz
>            Assignee: Gabriella Lotz
>            Priority: Major
>
> ksck, auto_rebalancer, and PartitionKey::DebugString() hex‑encode range/hash 
> keys by streaming raw bytes into ostringstream. If char is signed and the 
> range key contains bytes ≥ 0x80, the current 
> static_cast<uint16_t>(range_key_begin[i]) will sign‑extend, producing 
> incorrect hex output (e.g., ff becomes ffff). This is a correctness issue in 
> the encoded representation and can lead to inconsistent range tags between 
> components.
> Proposed fix: Use an unsigned byte cast before widening in both places, e.g.:
> static_cast<uint16_t>(static_cast<uint8_t>(range_key_begin[i]))
> or an equivalent helper to ensure 0–255 semantics.
> Locations:
> src/kudu/tools/ksck.cc (range_key_begin formatting)
> src/kudu/master/auto_rebalancer.cc (range_key_begin formatting)
> src/kudu/common/partition.cc (PartitionKey::DebugString())



--
This message was sent by Atlassian Jira
(v8.20.10#820010)

Reply via email to