https://issues.apache.org/jira/browse/KUDU-1374?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Jean-Daniel Cryans updated KUDU-1374:
-------------------------------------
Target Version/s: 0.9.0 (was: 0.8.0)
Adar told me I can move it to 0.9.0.
> Operations triggered by TS heartbeats may go unperformed
> --------------------------------------------------------
>
> Key: KUDU-1374
> URL: https://issues.apache.org/jira/browse/KUDU-1374
> Project: Kudu
> Issue Type: Sub-task
> Components: master
> Affects Versions: 0.7.1
> Reporter: Adar Dembo
> Assignee: Adar Dembo
> Priority: Critical
>
> (copying this from my multi-master design doc)
> The inclusion or exclusion of a tablet in an incremental tablet report is
> edge-triggered, and may result in a state changing operation on the tserver,
> communicated via out-of-band RPC. This RPC is retried until it is successful.
> However, if the leader master dies *after* it is able to respond to the
> tserver's heartbeat but *before* the out-of-band RPC is sent, the
> edge-triggered tablet report may be missed, and the state changing operation
> will not be performed until the next time the tablet is included in a tablet
> report. As tablet report inclusion criteria is narrow, operations may be
> "missed" for quite some time.
> These operations include:
> # Some tablet deletions, such as tablets belonging to orphaned tables, or
> tablets whose deletion RPCs were sent and failed during an earlier
> *DeleteTable()* request.
> # Some tablet alters, such as tablets whose alter RPCs were sent and failed
> during an earlier *AlterTable()* request.
> # Config changes sent due to under-replicated tablets.
> A simple fix is to require that tservers send a full tablet report when they
> detect that a new leader master was elected.
--
This message was sent by Atlassian JIRA