https://issues.apache.org/jira/browse/SUREFIRE-1302?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16009419#comment-16009419
 ] 

Tibor Digana commented on SUREFIRE-1302:
----------------------------------------

[~opeyrusse]
Can you pls build {{SUREFIRE-1302}} branch {{mvn -DskipTests install}} and test 
it with your project?
I will override the branch and add parameter soon and then I want to change the 
documentation.
Yet the ping timeout is adaptive.
Adding parameter takes time because several classes and reflection has to be 
changed.

https://git-wip-us.apache.org/repos/asf?p=maven-surefire.git;a=shortlog;h=refs/heads/SUREFIRE-1302

> Surefire does not wait long enough for the forked VM and assumes it to be dead
> ------------------------------------------------------------------------------
>
>                 Key: SUREFIRE-1302
>                 URL: https://issues.apache.org/jira/browse/SUREFIRE-1302
>             Project: Maven Surefire
>          Issue Type: Request
>          Components: Maven Surefire Plugin
>    Affects Versions: 2.19.1
>            Reporter: Yuriy Zaplavnov
>            Assignee: Tibor Digana
>             Fix For: 2.20.1
>
>         Attachments: 
> surefire-tests-terminated-master-aa9330316038f6b46316ce36ff40714ffc7cf299.zip,
>  tests_log_01.txt, tests_log_02.txt
>
>
> This issue happens because surefire kills the forked container if it times 
> out waiting for the 'ping'.
> In org.apache.maven.surefire.booter.ForkedBooter class there is hardcoded 
> constant PING_TIMEOUT_IN_SECONDS  = 20 which is used in the following method:
> {code}
> private static ScheduledFuture<?> listenToShutdownCommands( CommandReader 
> reader )
>     {
>         reader.addShutdownListener( createExitHandler( reader ) );
>         AtomicBoolean pingDone = new AtomicBoolean( true );
>         reader.addNoopListener( createPingHandler( pingDone ) );
>         return JVM_TERMINATOR.scheduleAtFixedRate( createPingJob( pingDone, 
> reader ),
>                                                    0,PING_TIMEOUT_IN_SECONDS, 
> SECONDS );
>     }
> {code}
> to create ScheduledFuture.
> In some of the cases the forked container might respond a bit later than it's 
> expected and surefire kills it
> {code}
> private static Runnable createPingJob( final AtomicBoolean pingDone, final 
> CommandReader reader  )
>     {
>         return new Runnable()
>         {
>             public void run()
>             {
>                 boolean hasPing = pingDone.getAndSet( false );
>                 if ( !hasPing )
>                 {
>                     exit( 1, KILL, reader, true );
>                 }
>             }
>         };
>     }
> {code}
> As long as we need to terminate it anyway, It would be really helpful if the 
> problem could be solved making the PING_TIMEOUT_IN_SECONDS  configurable with 
> the ability to specify the value from maven-surefire-plugin. 
> It would help to configure this timeout based on needs and factors of the 
> projects where surefire runs.



--
This message was sent by Atlassian JIRA
(v6.3.15#6346)

Reply via email to