https://issues.apache.org/jira/browse/WAGON-545?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16751254#comment-16751254
]
Christian Domsch commented on WAGON-545:
----------------------------------------
{quote}What version of HttpClient is being used by the Maven Wagon in this
particular case?{quote}
I am using standard maven 3.6.0, so wagon is 3.2.0. I am not sure, which
version of httpclient is used there, though.
{quote}Is there any chance it could be upgraded to 4.5.7?{quote}
How can I do that? I fell into a trap with maven extension while trying to
update wagon, before, so I am a bit hesitant.
> Connection reset while downloading artefacts in cloud environment (Azure)
> -------------------------------------------------------------------------
>
> Key: WAGON-545
> URL: https://issues.apache.org/jira/browse/WAGON-545
> Project: Maven Wagon
> Issue Type: Bug
> Components: wagon-http
> Affects Versions: 3.2.0
> Environment: Microsoft Azure 'Hosted VS2017'
> Reporter: Christian Domsch
> Priority: Major
> Fix For: waiting-for-feedback
>
> Attachments: log_10_310.zip, log_10_311.zip
>
>
> We are building a huge multi-module project in the azure cloud and experience
> random connection resets during our build due to probably the same issue as
> in WAGON-486. Since it is stated by Microsoft that they terminate connections
> that are idle for longer than four minutes (see solution comment
> [here|https://developercommunity.visualstudio.com/content/problem/357696/maven-project-build-failing-with-connection-reset.html],
> I set -Dmaven.wagon.httpconnectionManager.ttlSeconds=120. Also, disabling
> the http pool does not solve the problem. Attached are logs from out main
> build with logging turned on for the wagon components, as mentioned in the
> comment section of WAGON-486.
--
This message was sent by Atlassian JIRA
(v7.6.3#76005)