Alexander Rukletsov commented on MESOS-1571:
--------------------------------------------

So we have shutdown timeout on three levels: slave, basic executor (via 
ExecutorProcess) and optionally concrete executor (e.g. CommandExecutor). I 
would suggest we leave one configurable parameter—EXECUTOR_SHUTDOWN_TIMEOUT—on 
the basic executor level and calculate two other using fixed deltas. This 
parameter can be set via slave cmd parameters and overridden via protobuf 
message (TaskInfo?). Any other thoughts?

> Signal escalation timeout is not configurable
> ---------------------------------------------
>
>                 Key: MESOS-1571
>                 URL: https://issues.apache.org/jira/browse/MESOS-1571
>             Project: Mesos
>          Issue Type: Bug
>            Reporter: Niklas Quarfot Nielsen
>            Assignee: Alexander Rukletsov
>
> Even though the executor shutdown grace period is set to a larger interval, 
> the signal escalation timeout will still be 3 seconds. It should either be 
> configurable or dependent on EXECUTOR_SHUTDOWN_GRACE_PERIOD.
> Thoughts?



--