https://issues.apache.org/jira/browse/MESOS-4862?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15179057#comment-15179057
 ] 

Timothy Chen commented on MESOS-4862:
-------------------------------------

I think we should make framework timeout int64 instead of a double, I don't 
think we really need that much precision for failover timeout, and the cost of 
doing so causes problem like this.

> Setting failover_timeout in FrameworkInfo to Double.MAX_VALUE causes it to be 
> set to zero
> -----------------------------------------------------------------------------------------
>
>                 Key: MESOS-4862
>                 URL: https://issues.apache.org/jira/browse/MESOS-4862
>             Project: Mesos
>          Issue Type: Bug
>          Components: master, stout
>            Reporter: Timothy Chen
>
> Currently we expose framework failover_timeout as a double in Proto, and if 
> users set the failover_timeout to Double.MAX_VALUE, the Master will actually 
> set it to zero which is the complete opposite of the original intent.
> The problem is that in stout/duration.hpp we only store down to the 
> nanoseconds with int64_t, and it gives an error when we pass double.max as it 
> goes out of the int64_t bounds.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to