https://issues.apache.org/jira/browse/MESOS-4862?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15179057#comment-15179057
]
Timothy Chen commented on MESOS-4862:
-------------------------------------
I think we should make framework timeout int64 instead of a double, I don't
think we really need that much precision for failover timeout, and the cost of
doing so causes problem like this.
> Setting failover_timeout in FrameworkInfo to Double.MAX_VALUE causes it to be
> set to zero
> -----------------------------------------------------------------------------------------
>
> Key: MESOS-4862
> URL: https://issues.apache.org/jira/browse/MESOS-4862
> Project: Mesos
> Issue Type: Bug
> Components: master, stout
> Reporter: Timothy Chen
>
> Currently we expose framework failover_timeout as a double in Proto, and if
> users set the failover_timeout to Double.MAX_VALUE, the Master will actually
> set it to zero which is the complete opposite of the original intent.
> The problem is that in stout/duration.hpp we only store down to the
> nanoseconds with int64_t, and it gives an error when we pass double.max as it
> goes out of the int64_t bounds.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)