https://issues.apache.org/jira/browse/MESOS-5759?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15359482#comment-15359482
]
Joseph Wu commented on MESOS-5759:
----------------------------------
Any logs? (Preferably {{GLOG_v=2}})
> ProcessRemoteLinkTest.RemoteUseStaleLink and RemoteStaleLinkRelink are flaky
> ----------------------------------------------------------------------------
>
> Key: MESOS-5759
> URL: https://issues.apache.org/jira/browse/MESOS-5759
> Project: Mesos
> Issue Type: Bug
> Components: libprocess, test
> Affects Versions: 1.0.0
> Reporter: Joseph Wu
> Assignee: Joseph Wu
> Labels: libprocess, mesosphere
>
> {{ProcessRemoteLinkTest.RemoteUseStaleLink}} and
> {{ProcessRemoteLinkTest.RemoteStaleLinkRelink}} are failing occasionally with
> the error:
> {code}
> [ RUN ] ProcessRemoteLinkTest.RemoteStaleLinkRelink
> WARNING: Logging before InitGoogleLogging() is written to STDERR
> I0630 07:42:34.661110 18888 process.cpp:1066] libprocess is initialized on
> 172.17.0.2:56294 with 16 worker threads
> E0630 07:42:34.666393 18765 process.cpp:2104] Failed to shutdown socket with
> fd 7: Transport endpoint is not connected
> /mesos/3rdparty/libprocess/src/tests/process_tests.cpp:1059: Failure
> Value of: exitedPid.isPending()
> Actual: false
> Expected: true
> [ FAILED ] ProcessRemoteLinkTest.RemoteStaleLinkRelink (56 ms)
> {code}
> There appears to be a race between establishing a socket connection and the
> test calling {{::shutdown}} on the socket. Under some circumstances, the
> {{::shutdown}} may actually result in failing the future in
> {{SocketManager::link_connect}} error and thereby trigger
> {{SocketManager::close}}.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)