Yan Xu created MESOS-7215:
-----------------------------
Summary: Master sends ShutdownFrameworkMessage for all
partition-aware frameworks
Key: MESOS-7215
URL: https://issues.apache.org/jira/browse/MESOS-7215
Project: Mesos
Issue Type: Bug
Reporter: Yan Xu
Prior to the partition-awareness work MESOS-5344, upon agent reregistration
after it has been removed, the master only sends ShutdownFrameworkMessages to
the agent for frameworks that it knows have been torn down.
With the new logic in MESOS-5344, Mesos is now sending
{{ShutdownFrameworkMessages}} to the agent for all non-partition-aware
frameworks (including the ones that are still registered)
This is problematic. The offer from this agent can still go to the same
framework which can then launch new tasks. The agent then receives tasks of the
same framework and ignores them because it thinks the framework is shutting
down. The framework is not shutting down of course, so from the master and the
scheduler's perspective the task is pending in STAGING forever until the next
agent reregistration, which could happen much later.
This also makes the semantics of `ShutdownFrameworkMessage` ambiguous: the
agent is assuming the framework to be going away (and act accordingly) when
it's not.
--
This message was sent by Atlassian JIRA
(v6.3.15#6346)