https://issues.apache.org/jira/browse/NIFI-9049?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Nathan Gough updated NIFI-9049:
-------------------------------
    Fix Version/s: 1.15.0

> SingleUserAuthorizer allows unauthorised access after NiFi restart (and user 
> credentials may be lost)
> -----------------------------------------------------------------------------------------------------
>
>                 Key: NIFI-9049
>                 URL: https://issues.apache.org/jira/browse/NIFI-9049
>             Project: Apache NiFi
>          Issue Type: Bug
>    Affects Versions: 1.14.0, 1.15.0
>            Reporter: Chris Sampson
>            Assignee: David Handermann
>            Priority: Major
>             Fix For: 1.15.0
>
>          Time Spent: 1h 20m
>  Remaining Estimate: 0h
>
> Having started a new instance of NiFi (using the latest development version 
> from {{main}}) with the default SingleUserAuthorizer setup, then restarting 
> the instance (after updating an unrelated NAR in the lib/ folder), I was 
> still able to access the NiFi UI without re-authenticating through my browser 
> *but* I was unable to view any content because "unathorised access has not 
> been enabled".
> This is confusing - if I'm unauthorised, how am I able to access the UI at 
> all, Stop/Start processors and reconfigure them, etc.?
> I suspect this is something to do with the browser caching a NiFi JWT from 
> the initial login for a time, then the UI seeing that I've got a JWT and 
> allowing me access, but then denying content-based access when trying to view 
> those screens because my JWT is no longer valid (or something like that - but 
> this is a guess and with no real evidence to support it).
> *Also* the default username/password is only output to the logs during the 
> first startup of the instance. These logs may not be persisted in Docker 
> images, so users would not be able to obtain them after a restart and 
> therefore would not be able to re-authenticate if they didn't know/think to 
> write them down anywhere (but the user/auth configuration has been persisted 
> through a restart in an externalised volume along with the {{flow.xml.gz}}, 
> etc.). Also, even if the log files are persisted (in Docker or on a 
> bare-metal install), the log files rotate and delete after a while, so again 
> the username/password would be lost (possibly before the default dev user 
> credential expire) - this could cause problems for users.
> The authorisation issue also impacts one's ability to download Templates or 
> Flow Definitions from the NiFi UI.
> To reproduce:
> * Run NiFi (with default SingleUserAuthorizer)
> * Obtain username/password from logs
> * Login to the NiFi UI
> * Create a basic Flow (e.g. GenerateFlowFile => Funnel) and leave data in a 
> queue
> * View FlowFile content from within the queue (List Queue => View)
> * Stop NiFi
> * Wait some time (I'm not sure how long a time is necessary, think I might 
> have witnessed this after several hours of my NiFi instance being offline and 
> a computer restart before the problem manifested)
> * Restart NiFi
> * Refresh browser tab
> * Stop/Start/reconfigure Flow
> * Attempt to view FlowFile content (observe error message)



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to