https://issues.apache.org/ooo/show_bug.cgi?id=122676
Bug ID: 122676
Issue Type: DEFECT
Summary: undo-redo works correctly only after double click
Product: Impress
Version: AOO400-dev
Hardware: PC
OS: Windows 7
Status: UNCONFIRMED
Severity: trivial
Priority: P3
Component: ui
Assignee: [email protected]
Reporter: [email protected]
CC: [email protected]
Created attachment 80993
--> https://issues.apache.org/ooo/attachment.cgi?id=80993&action=edit
Attachment showing when undo button clicked 1 time
Overview: while executing AOOTest-1429 Undo and Redo functionality works
normally as it should be only if Undo and Redo command button clicked 2 times.
Steps to Reproduce:
1) Open a new presentation.
2) Insert a drawing object, or a text box, or a fontwork, and keep focus on
it
3) change fill type in area section of sidebar ,let say change it to
gradient( default fill type is color )
4) Press undo button.
5) press redo button.
Actual Results: After pressing undo button area section showing gradient fill
type.
Expected Results: After pressing undo button area section should show color
fill type.
NOTES:
Instead of reverting back to color fill type, the fill type remains gradient
doesn’t get reverted to its original fill type (color).when clicking 1 more
time on undo button the fill type changes to color .
Same with redo command.Its also works correctly only if it clicked 2 times to
get the expected result.
Build Date & Hardware:
Build: AOO 4.0 Rev. 1489073
OS: windows 7
Test case Reference :Test Case ID AOOTest-1429 :: Version : 1
Area section - Impress - undo/redo operations
--
You are receiving this mail because:
You are on the CC list for the bug.
You are the assignee for the bug.