Chung-En Lee created HDDS-17140:
-----------------------------------
Summary: S3 Gateway does not pick up the new OM version after ZDU
finalization
Key: HDDS-17140
URL: https://issues.apache.org/jira/browse/HDDS-17140
Project: Apache Ozone
Issue Type: Bug
Reporter: Chung-En Lee
The ZDU design doc ("Order of Operations During the Upgrade", step 5) says to
rolling-restart S3 Gateway and other client processes on the new software
before the cluster is finalized. At that point OM is still pre-finalized, so it
reports the old version to clients.
S3 Gateway learns the OM version only once, when it handles its first request
after starting, and keeps it for the life of the process. In a ZDU rolling
restart S3 Gateway keeps serving traffic, so it captures the old version before
finalization. After the admin finalizes the cluster, OM reports the new
version, but S3 Gateway keeps the old one. Any new feature that depends on the
finalized OM version stays disabled in S3 Gateway until it is restarted again.
Proposed fix (options):
1. Change the documented upgrade order so S3 Gateway is restarted after
finalization.
2. Keep the current order, and document that S3 Gateway must be restarted again
after finalization.
3. Make S3 Gateway aware OM version changes (e.g. after finalization) and
re-initialize its OzoneClient automatically, so it picks up the latest OM
version without a manual restart.
--