symious opened a new pull request, #3983: URL: https://github.com/apache/ozone/pull/3983
## What changes were proposed in this pull request? When SCM is upgraded with new LayoutVersion, old datanode won't be able to register to the new SCM, thus the new SCM change to safemode and the cluster becomes unavailable. ## What is the link to the Apache JIRA https://issues.apache.org/jira/browse/HDDS-7520 ## How was this patch tested? Removed the restrictive unit test. -- This is an automated message from the Apache Git Service. To respond to the message, please log on to GitHub and use the URL above to go to the specific comment. To unsubscribe, e-mail: [email protected] For queries about this service, please contact Infrastructure at: [email protected] --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]