reswqa commented on code in PR #1230:
URL: https://github.com/apache/incubator-paimon/pull/1230#discussion_r1205805294


##########
paimon-flink/paimon-flink-common/src/main/java/org/apache/paimon/flink/source/AbstractDataTableSource.java:
##########
@@ -214,7 +214,7 @@ private DataStream<RowData> configureSource(
             FlinkSourceBuilder sourceBuilder, StreamExecutionEnvironment env) {
         Options options = Options.fromMap(this.table.options());
         Integer parallelism = 
options.get(FlinkConnectorOptions.SCAN_PARALLELISM);
-        if (options.get(FlinkConnectorOptions.INFER_SCAN_PARALLELISM)) {
+        if (parallelism == null && 
options.get(FlinkConnectorOptions.INFER_SCAN_PARALLELISM)) {

Review Comment:
   It seems that we did not perform boundary check(e.g. `>0`) on `parallelism`. 
If `SCAN_PARALLELISM` is set to `-1`, 
`OperatorValidationUtils.validateParallelism` will not reject it because it is 
equal to `ExecutionConfig.PARALLELISM_DEFAULT`, which may cause some confusion. 
But it can always be argued that this is the behavior supported by `flink` 
(`-1` is considered the default parallelism). Just a comment, maybe not do this 
check here is exactly the right one. 🤔 



-- 