https://issues.apache.org/jira/browse/PLC4X-259?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Christofer Dutz updated PLC4X-259:
----------------------------------
    Description: 
In order to finally be able to release, we need to test the different types of 
data in all of our drivers:

 
h1. Beckhoff ADS
||Datatype||Implemented||Read||Write||
|BOOL|(/)|(/)|
|BYTE|(/)|(/)|
|WORD|(/)|(/)|
|DWORD|(/)|(/)|
|LWORD|(x)| |
|SINT|(/)|(/)|
|USINT|(/)|(/)|
|INT|(/)|(/)|
|UINT|(/)|(/)|
|DINT|(/)|(/)|
|UDINT|(/)|(/)|
|LINT|(/)|(/)|
|ULINT|(/)|(/)|
|REAL|(/)|(/)|
|LREAL|(/)|(/)|
|CHAR|(x)|
|WCHAR|(x)|
|STRING|(x)|
|WSTRING|(x)|
|TIME|(/)|(/)|
|LTIME|(x)|(/)|
|DATE|(/)|(/)|
|LDATE|(x)| |
|TIME_OF_DAY / TOD|(/)|(/)|
|LTIME_OF_DAY / LTOD|(x)| |
|DATE_AND_TIME / DT|(/)|(/)|
|LDATE_AND_TIME / LDT|(x)| |
h1. Siemens S7
||Datatype||Implemented||Read||Write||
|BOOL|(/)| | |
|BYTE|(/)| | |
|WORD|(/)| | |
|DWORD|(/)| | |
|LWORD|(!)| | |
|SINT|(/)| | |
|USINT|(/)| | |
|INT|(/)| | |
|UINT|(/)| | |
|DINT|(/)| | |
|UDINT|(/)| | |
|LINT|(!)| | |
|ULINT|(!)| | |
|REAL|(/)| | |
|LREAL|(!)| | |
|CHAR| | | |
|WCHAR| | | |
|STRING|(/)| | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |
h1.  Modbus
||Datatype||Implemented||Read||Write||
|BOOL| | | |
|BYTE| | | |
|WORD| | | |
|DWORD| | | |
|LWORD| | | |
|SINT| | | |
|USINT| | | |
|INT| | | |
|UINT| | | |
|DINT| | | |
|UDINT| | | |
|LINT| | | |
|ULINT| | | |
|REAL| | | |
|LREAL| | | |
|CHAR| | | |
|WCHAR| | | |
|STRING| | | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |
h1.  KNX
||Datatype||Implemented||Read||Write||
|BOOL| | | |
|BYTE| | | |
|WORD| | | |
|DWORD| | | |
|LWORD| | | |
|SINT| | | |
|USINT| | | |
|INT| | | |
|UINT| | | |
|DINT| | | |
|UDINT| | | |
|LINT| | | |
|ULINT| | | |
|REAL| | | |
|LREAL| | | |
|CHAR| | | |
|WCHAR| | | |
|STRING| | | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |
h1.  Firmata
||Datatype||Implemented||Read||Write||
|BOOL| | | |
|BYTE| | | |
|WORD| | | |
|DWORD| | | |
|LWORD| | | |
|SINT| | | |
|USINT| | | |
|INT| | | |
|UINT| | | |
|DINT| | | |
|UDINT| | | |
|LINT| | | |
|ULINT| | | |
|REAL| | | |
|LREAL| | | |
|CHAR| | | |
|WCHAR| | | |
|STRING| | | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |

  was:
In order to finally be able to release, we need to test the different types of 
data in all of our drivers:

 
h1. Beckhoff ADS
||Datatype||Implemented||Read||Write||
|BOOL|(/)|(/)|
|BYTE|(/)|(/)|
|WORD|(/)|(/)|
|DWORD|(/)|(/)|
|LWORD|(x)| |
|SINT|(/)|(/)|
|USINT|(/)|(/)|
|INT|(/)|(/)|
|UINT|(/)|(/)|
|DINT|(/)|(/)|
|UDINT|(/)|(/)|
|LINT|(/)|(/)|
|ULINT|(/)|(/)|
|REAL|(/)|(/)|
|LREAL|(/)|(/)|
|CHAR|(x)|
|WCHAR|(x)|
|STRING|(x)|
|WSTRING|(x)|
|TIME|(/)|(/)|
|LTIME|(/)|(/)|
|DATE|(/)|(/)|
|TIME_OF_DAY|(/)|(/)|
|DATE_AND_TIME|(/)|(/)|
h1. Siemens S7
||Datatype||Implemented||Read||Write||
|BOOL|(/)| | |
|BYTE|(/)| | |
|WORD|(/)| | |
|DWORD|(/)| | |
|LWORD|(!)| | |
|SINT|(/)| | |
|USINT|(/)| | |
|INT|(/)| | |
|UINT|(/)| | |
|DINT|(/)| | |
|UDINT|(/)| | |
|LINT|(!)| | |
|ULINT|(!)| | |
|REAL|(/)| | |
|LREAL|(!)| | |
|CHAR| | | |
|WCHAR| | | |
|STRING|(/)| | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |
h1.  Modbus
||Datatype||Implemented||Read||Write||
|BOOL| | | |
|BYTE| | | |
|WORD| | | |
|DWORD| | | |
|LWORD| | | |
|SINT| | | |
|USINT| | | |
|INT| | | |
|UINT| | | |
|DINT| | | |
|UDINT| | | |
|LINT| | | |
|ULINT| | | |
|REAL| | | |
|LREAL| | | |
|CHAR| | | |
|WCHAR| | | |
|STRING| | | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |
h1.  KNX
||Datatype||Implemented||Read||Write||
|BOOL| | | |
|BYTE| | | |
|WORD| | | |
|DWORD| | | |
|LWORD| | | |
|SINT| | | |
|USINT| | | |
|INT| | | |
|UINT| | | |
|DINT| | | |
|UDINT| | | |
|LINT| | | |
|ULINT| | | |
|REAL| | | |
|LREAL| | | |
|CHAR| | | |
|WCHAR| | | |
|STRING| | | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |
h1.  Firmata
||Datatype||Implemented||Read||Write||
|BOOL| | | |
|BYTE| | | |
|WORD| | | |
|DWORD| | | |
|LWORD| | | |
|SINT| | | |
|USINT| | | |
|INT| | | |
|UINT| | | |
|DINT| | | |
|UDINT| | | |
|LINT| | | |
|ULINT| | | |
|REAL| | | |
|LREAL| | | |
|CHAR| | | |
|WCHAR| | | |
|STRING| | | |
|WSTRING| | | |
|TIME| | | |
|LTIME| | | |
|DATE| | | |
|TIME_OF_DAY| | | |
|DATE_AND_TIME| | | |


> Test all supported datatypes on all of our drivers
> --------------------------------------------------
>
>                 Key: PLC4X-259
>                 URL: https://issues.apache.org/jira/browse/PLC4X-259
>             Project: Apache PLC4X
>          Issue Type: Task
>          Components: Driver-ADS, Driver-Ethernet/IP, Driver-KNX, 
> Driver-Modbus, Driver-OPC-UA, Driver-S7
>    Affects Versions: 0.8.0
>            Reporter: Christofer Dutz
>            Assignee: Christofer Dutz
>            Priority: Major
>             Fix For: 0.8.0
>
>
> In order to finally be able to release, we need to test the different types 
> of data in all of our drivers:
>  
> h1. Beckhoff ADS
> ||Datatype||Implemented||Read||Write||
> |BOOL|(/)|(/)|
> |BYTE|(/)|(/)|
> |WORD|(/)|(/)|
> |DWORD|(/)|(/)|
> |LWORD|(x)| |
> |SINT|(/)|(/)|
> |USINT|(/)|(/)|
> |INT|(/)|(/)|
> |UINT|(/)|(/)|
> |DINT|(/)|(/)|
> |UDINT|(/)|(/)|
> |LINT|(/)|(/)|
> |ULINT|(/)|(/)|
> |REAL|(/)|(/)|
> |LREAL|(/)|(/)|
> |CHAR|(x)|
> |WCHAR|(x)|
> |STRING|(x)|
> |WSTRING|(x)|
> |TIME|(/)|(/)|
> |LTIME|(x)|(/)|
> |DATE|(/)|(/)|
> |LDATE|(x)| |
> |TIME_OF_DAY / TOD|(/)|(/)|
> |LTIME_OF_DAY / LTOD|(x)| |
> |DATE_AND_TIME / DT|(/)|(/)|
> |LDATE_AND_TIME / LDT|(x)| |
> h1. Siemens S7
> ||Datatype||Implemented||Read||Write||
> |BOOL|(/)| | |
> |BYTE|(/)| | |
> |WORD|(/)| | |
> |DWORD|(/)| | |
> |LWORD|(!)| | |
> |SINT|(/)| | |
> |USINT|(/)| | |
> |INT|(/)| | |
> |UINT|(/)| | |
> |DINT|(/)| | |
> |UDINT|(/)| | |
> |LINT|(!)| | |
> |ULINT|(!)| | |
> |REAL|(/)| | |
> |LREAL|(!)| | |
> |CHAR| | | |
> |WCHAR| | | |
> |STRING|(/)| | |
> |WSTRING| | | |
> |TIME| | | |
> |LTIME| | | |
> |DATE| | | |
> |TIME_OF_DAY| | | |
> |DATE_AND_TIME| | | |
> h1.  Modbus
> ||Datatype||Implemented||Read||Write||
> |BOOL| | | |
> |BYTE| | | |
> |WORD| | | |
> |DWORD| | | |
> |LWORD| | | |
> |SINT| | | |
> |USINT| | | |
> |INT| | | |
> |UINT| | | |
> |DINT| | | |
> |UDINT| | | |
> |LINT| | | |
> |ULINT| | | |
> |REAL| | | |
> |LREAL| | | |
> |CHAR| | | |
> |WCHAR| | | |
> |STRING| | | |
> |WSTRING| | | |
> |TIME| | | |
> |LTIME| | | |
> |DATE| | | |
> |TIME_OF_DAY| | | |
> |DATE_AND_TIME| | | |
> h1.  KNX
> ||Datatype||Implemented||Read||Write||
> |BOOL| | | |
> |BYTE| | | |
> |WORD| | | |
> |DWORD| | | |
> |LWORD| | | |
> |SINT| | | |
> |USINT| | | |
> |INT| | | |
> |UINT| | | |
> |DINT| | | |
> |UDINT| | | |
> |LINT| | | |
> |ULINT| | | |
> |REAL| | | |
> |LREAL| | | |
> |CHAR| | | |
> |WCHAR| | | |
> |STRING| | | |
> |WSTRING| | | |
> |TIME| | | |
> |LTIME| | | |
> |DATE| | | |
> |TIME_OF_DAY| | | |
> |DATE_AND_TIME| | | |
> h1.  Firmata
> ||Datatype||Implemented||Read||Write||
> |BOOL| | | |
> |BYTE| | | |
> |WORD| | | |
> |DWORD| | | |
> |LWORD| | | |
> |SINT| | | |
> |USINT| | | |
> |INT| | | |
> |UINT| | | |
> |DINT| | | |
> |UDINT| | | |
> |LINT| | | |
> |ULINT| | | |
> |REAL| | | |
> |LREAL| | | |
> |CHAR| | | |
> |WCHAR| | | |
> |STRING| | | |
> |WSTRING| | | |
> |TIME| | | |
> |LTIME| | | |
> |DATE| | | |
> |TIME_OF_DAY| | | |
> |DATE_AND_TIME| | | |



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to