https://issues.apache.org/jira/browse/RATIS-569?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Mukul Kumar Singh updated RATIS-569:
------------------------------------
Summary: StatusRuntimeException because Ratis clients do not shutdown the
observer cleanly (was: StatusRuntimeException on the datanode because clients
do not shutdown the observer cleanly.)
> StatusRuntimeException because Ratis clients do not shutdown the observer
> cleanly
> ---------------------------------------------------------------------------------
>
> Key: RATIS-569
> URL: https://issues.apache.org/jira/browse/RATIS-569
> Project: Ratis
> Issue Type: Bug
> Components: server
> Affects Versions: 0.3.0
> Reporter: Mukul Kumar Singh
> Assignee: Siddharth Wagle
> Priority: Blocker
> Labels: ozone
> Attachments: RATIS-569.01.patch, RATIS-569.02.patch,
> RATIS-569.03.patch
>
>
> Running TestDataValidate in Ozone leads to StatusRuntimeException on the
> datanode frequently.
> This causes an unclean shutdown on the stream on the datanode.
> In GrpcClientProtocolClient, shutdownNow should be followed by a
> awaitTermination to wait for a clean shutdown.
--
This message was sent by Atlassian Jira
(v8.3.2#803003)