Peter Toth created SPARK-59949:
----------------------------------

             Summary: Record the `operator.sdk` controller execution histograms 
with sub-second precision
                 Key: SPARK-59949
                 URL: https://issues.apache.org/jira/browse/SPARK-59949
             Project: Spark
          Issue Type: Sub-task
          Components: Kubernetes
    Affects Versions: kubernetes-operator-1.0.0
            Reporter: Peter Toth


- {{OperatorJosdkMetrics.timeControllerExecution}} updates its histograms with 
{{toSeconds(startTime)}}, which is {{TimeUnit.MILLISECONDS.toSeconds(...)}}. So 
the elapsed time is cut down to whole seconds, and a reconcile under one second 
records 0.
- Most reconciles take well under a second. So the quantiles of these 
histograms are mostly 0, and their Prometheus {{_sum}} (SPARK-59935) 
undercounts.
- Recording nanoseconds in a histogram whose name contains {{nanos}} would fix 
it, since {{PrometheusPullModelHandler}} then exports seconds. The name change 
is user-facing, so it needs a migration guide entry.
- This is there since SPARK-48984 (0.1.0).

Found while reviewing 
https://github.com/apache/spark-kubernetes-operator/pull/922.




--