https://issues.apache.org/jira/browse/SPARK-10439?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=14737772#comment-14737772
]
Marcelo Vanzin commented on SPARK-10439:
----------------------------------------
Davies filed SPARK-10522 to track the negative nanoseconds issue with Hive;
I'll leave this open to track the fix (if any) to the possible overflows in the
code.
> Catalyst should check for overflow / underflow of date and timestamp values
> ---------------------------------------------------------------------------
>
> Key: SPARK-10439
> URL: https://issues.apache.org/jira/browse/SPARK-10439
> Project: Spark
> Issue Type: Bug
> Components: SQL
> Affects Versions: 1.5.0
> Reporter: Marcelo Vanzin
> Priority: Minor
>
> While testing some code, I noticed that a few methods in {{DateTimeUtils}}
> are prone to overflow and underflow.
> For example, {{millisToDays}} can overflow the return type ({{Int}}) if a
> large enough input value is provided.
> Similarly, {{fromJavaTimestamp}} converts milliseconds to microseconds, which
> can overflow if the input is {{> Long.MAX_VALUE / 1000}} (or underflow in the
> negative case).
> There might be others but these were the ones that caught my eye.
--