Prasanth Jayachandran created TEZ-2171:
------------------------------------------

             Summary: LLAP: DefaultMetricsSystem.shutdown() should not be 
called in TezChild
                 Key: TEZ-2171
                 URL: https://issues.apache.org/jira/browse/TEZ-2171
             Project: Apache Tez
          Issue Type: Bug
    Affects Versions: 0.7.0
            Reporter: Prasanth Jayachandran


DefaultMetricsSystem.shutdown() is called in TezChild. IIUC, shutdown is meant 
to be called in daemon context (datanode/namenode). LLAP daemon initializes the 
metrics system, after running the first query TezChild shuts down the metrics 
system which results in closing of all metrics endpoints/sinks. 



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)