Masakazu Kitajo created TS-3811:
-----------------------------------
Summary: HTTP/2 window size must not exceed 2^31-1
Key: TS-3811
URL: https://issues.apache.org/jira/browse/TS-3811
Project: Traffic Server
Issue Type: Improvement
Components: HTTP/2
Reporter: Masakazu Kitajo
https://tools.ietf.org/html/rfc7540#section-6.9.1
{quote}
A sender MUST NOT allow a flow-control window to exceed 2^31-1
octets. If a sender receives a WINDOW_UPDATE that causes a flow-
control window to exceed this maximum, it MUST terminate either the
stream or the connection, as appropriate. For streams, the sender
sends a RST_STREAM with an error code of FLOW_CONTROL_ERROR; for the
connection, a GOAWAY frame with an error code of FLOW_CONTROL_ERROR
is sent.
{quote}
Currently, TS accepts such a invalid flow control.
It would cause overflow but is not critical, so I'm setting issue type as
Improvement.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)