Bryan Call created TS-4324:
------------------------------
Summary: Inefficient way of transferring data frames
Key: TS-4324
URL: https://issues.apache.org/jira/browse/TS-4324
Project: Traffic Server
Issue Type: Improvement
Components: HTTP/2
Reporter: Bryan Call
ATS transfers data 8K - 9 bytes (http/2 header size) and then sends the 9 bytes
is couldn't write in a new frame that only has 9 bytes. This also happens if
you bump up the buffer size to 16K.
{code}
[ 1.036] recv DATA frame <length=8183, flags=0x00, stream_id=13>
[ 1.036] recv DATA frame <length=9, flags=0x00, stream_id=13>
[ 1.259] recv DATA frame <length=8183, flags=0x00, stream_id=13>
[ 1.259] recv DATA frame <length=9, flags=0x00, stream_id=13>
[ 1.259] recv DATA frame <length=8183, flags=0x00, stream_id=13>
[ 1.259] recv DATA frame <length=9, flags=0x00, stream_id=13>
{code}
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)