https://issues.apache.org/jira/browse/TRAFODION-975?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Hans Zeller updated TRAFODION-975:
----------------------------------
    Issue Type: Sub-task  (was: Bug)
        Parent: TRAFODION-13

> LP Bug: 1417739 - Multi-temperature data: should not allow divisioning on 
> float datatype.
> -----------------------------------------------------------------------------------------
>
>                 Key: TRAFODION-975
>                 URL: https://issues.apache.org/jira/browse/TRAFODION-975
>             Project: Apache Trafodion
>          Issue Type: Sub-task
>          Components: sql-cmp
>            Reporter: Julie Thai
>            Assignee: Hans Zeller
>
> Should not allow divisioning on float datatype. Rounding errors could in some 
> extreme cases lead to inconsistent data in a table (e.g. two rows with the 
> same primary key).
> >>CREATE  TABLE mtderr(store_id integer not null,
> +>item_id  integer not null,
> +>sale_date date default date '2000-01-01' not null ,
> +>sale_amt double precision not null,
> +>quantity integer not null,
> +>PRIMARY KEY (store_id, sale_amt))
> +>DIVISION BY ((sale_amt + 182.0)/182.0);
> --- SQL operation complete.
> To reproduce:
> CREATE  TABLE mtderr(store_id integer not null,
> item_id  integer not null,
> sale_date date default date '2000-01-01' not null ,
> sale_amt double precision not null,
> quantity integer not null,
> PRIMARY KEY (store_id, sale_amt))
> DIVISION BY ((sale_amt + 182.0)/182.0);



--
This message was sent by Atlassian JIRA