Key Messages ----------------------- This is first sanity testing for Tizen IVI M14.2 with Crosswalk. Crosswalk was landed in repo but not integrated in the image, QA installed it manually and its basic function works. Web app installation has dependence issue(TIVI-3128<https://bugs.tizen.org/jira/browse/TIVI-3128>) and it also blocked Modello UI testing. Web app failed to launch in ICO homescreen with Crosswalk(TIVI-3132<https://bugs.tizen.org/jira/browse/TIVI-3132>). Moreover, 2 regression issues were caught : no audio heard for HFP voice call(TIVI-3129<https://bugs.tizen.org/jira/browse/TIVI-3129>), lemolo UI also has wrong status(TIVI-3131<https://bugs.tizen.org/jira/browse/TIVI-3131>)
Issue Summary ----------------------- Regression issues: TIVI-3131<https://bugs.tizen.org/jira/browse/TIVI-3131> [REG] Lemolo dialer UI status does not change after create/answer voice call. TIVI-3129<https://bugs.tizen.org/jira/browse/TIVI-3129> [REG]No audio heard on IVI during HFP voice call New issues: TIVI-3132<https://bugs.tizen.org/jira/browse/TIVI-3132> GhostCluster app is failed to be launched on ICO homescreen TIVI-3128<https://bugs.tizen.org/jira/browse/TIVI-3128> Fail to install webapp due to the dependence of wrt-installer TIVI-3127<https://bugs.tizen.org/jira/browse/TIVI-3127> [Crosswalk] GhostCluster UI doesn't render fully Reopen issues: N/A Verify issues: N/A Key issues: TIVI-3132<https://bugs.tizen.org/jira/browse/TIVI-3132> GhostCluster app is failed to be launched on ICO homescreen TIVI-3131<https://bugs.tizen.org/jira/browse/TIVI-3131> [REG] Lemolo dialer UI status does not change after create/answer voice call. TIVI-3129<https://bugs.tizen.org/jira/browse/TIVI-3129> [REG]No audio heard on IVI during HFP voice call TIVI-3128<https://bugs.tizen.org/jira/browse/TIVI-3128> Fail to install webapp due to the dependence of wrt-installer TIVI-3127<https://bugs.tizen.org/jira/browse/TIVI-3127> [Crosswalk] GhostCluster UI doesn't render fully TIVI-2942<https://bugs.tizen.org/jira/browse/TIVI-2942> The audio of 2G/3G voicecall does not work with Telit HE910 Modem Test Result: ---------------------- Image version 20140506.3 Total test cases 47 Passed 38 Failed 5 Blocked 4 Run rate 91% Pass rate of total 81% Pass rate of executed 88% For detail information, please refer to link below: https://qarpt.tizen.org/3.0/IVI/Sanity%20Test/VTC1010/593 Workaround: 1. Install ICO Homescreen: Launch Wayland Terminal and execute "root:~> zypper install ico-uxf-homescreen" and select "Solution 1". 2. Unmute alsa after system reboot: Launch Wayland Terminal and execute: "pacmd set-sink-mute 0 false". 3. Disable VGA output by adding "video=VGA-1:d" to the kernel command line. Test Environment ----------------------- Image tested: https://download.tizen.org/releases/daily/tizen/ivi/ivi/tizen_20140506.3/images/ Hardware: VTC1010+FHD touch monitor NDiS 166+Chelong touch monitor VTC7120 BK VTC7120 D1K Test Objective ----------------------- Sanity test is a very brief run-through of the functionality of the entire Tizen IVI image, to assure that the basic health of the distribution and report major regressions at the earliest time. All the checkpoints in sanity test reflect the most important and basic functionality, stability of the distribution. Best Regards Jinyan
_______________________________________________ IVI mailing list [email protected] https://lists.tizen.org/listinfo/ivi