Thank you Ossama, Now it works thanks to your example it's obvious.
2014-05-14 12:13 GMT+02:00 ismail yildiz <[email protected]>: > Sorry for my late answers ... I tried both solution but nothing work ... > Transform 90 swap my display and it´s not my problem. I made the 99-rules > with calibration value and nothing change. > Maybe I need to put a swapXY in this ? But how ? > > Le mercredi 7 mai 2014, Othman, Ossama <[email protected]> a écrit : > > Hi Manuel, >> >> On Wed, May 7, 2014 at 4:44 AM, Manuel Bachmann < >> [email protected]> wrote: >> >>> Hi Ismail, >>> >>> Weston deduces the (x,y) coordinates from the the touchscreen, which is >>> handled separately from the screen itself. It has no relation to the actual >>> display, you may think of it as an USB drawing tablet which happens to be >>> transparent and positioned over the real screen. >>> >>> Here, it looks like it is configured incorrectly. >>> >>> You have 2 ways to solve this problem : >>> >>> - flip Weston itself, by specifying in "transform=90" in >>> "/etc/xdg/weston/weston.ini" >>> >>> - fix the touchscreen itself, for example by modifying its drivers >>> parameters so it flips (look for instance at >>> https://wiki.archlinux.org/index.php/touchscreen, "options >>> usbtouchscreen swap_xy=1" which *may* apply) >>> >> >> The weston-calibrator takes into account inverted axes. The calibration >> output just needs to be added to an appropriate udev rules file through an >> ENV{WL_CALIBRATION} value. >> >> >
_______________________________________________ IVI mailing list [email protected] https://lists.tizen.org/listinfo/ivi