On Mon, Jan 12, 2009 at 10:15 AM, Al McIntosh <[email protected]> wrote: > Hi, > Every now and then after a reboot, the captured video is simply a green or > pink screen. I have found if I unload the cx18 module and reload it, this > will resolve the pink or green screen and capture returns to normal. > Typically, if I shut down the computer safely and reboot video capture is > fine at reboot. I wonder if this related to the module not safely unloading. > > I am in the habit of testing video capture after a reboot in case I need to > reload the modules. However, There was a power outage in my area Friday and > I have a weekends worth of green video shows. :( My UPS died recently.... > > I have also noticed this happens if I switch the HVR1600 to another PCI > slot. > > or > > Pull the HVR-1600 and place another device on the same slot boot the > computer then place the HVR-1600 back into the same slot and boot. >
This is a known issue. There is a script on the hvr-1600 wiki page that with put in startup, does a few second grab on boot. -Mark _______________________________________________ ivtv-users mailing list [email protected] http://ivtvdriver.org/mailman/listinfo/ivtv-users