[email protected] wrote:
> Revision: 1504
> Author: eur.van.andel
> Date: Thu Nov 26 15:56:22 2009
> Log: added temperatures to humidity sample, lowered readout frequency to  
> prevent self-heating
> 


Sample does not compile:

> jal 2.4l (compiled Aug  7 2009)
> generating p-code
> 16f876a_sht.jal:115: "read_celsius_temp_sht" not defined
> 16f876a_sht.jal:115: Too many parameters (0 expected, 1 found)
> 16f876a_sht.jal:122: "read_centicelsius_temp_sht" not defined
> 16f876a_sht.jal:122: Too many parameters (0 expected, 1 found)
> 4 errors, 0 warnings


-- 
Rob Hamerling, Vianen, NL (http://www.robh.nl/)

--

You received this message because you are subscribed to the Google Groups 
"jallib" group.
To post to this group, send email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/jallib?hl=en.