hi Eur,

Why did you stop on all yours/Roman Black bresenham libraries to generate 1
second?
If you generate 1milisecond (or less) instead, you have a real time library
process usefull for something else than clock, then maybe the question of
how long  the ISR can be, may be actual.

Vasile

On Sat, Jul 31, 2010 at 3:13 PM, <[email protected]> wrote:

> Revision: 2170
> Author: eur.van.andel
> Date: Sat Jul 31 15:12:29 2010
> Log:  made a new all-jal, 5 line RTC ISR with TMR3, needs 50 lines comment
>
> http://code.google.com/p/jallib/source/detail?r=2170
>
> Added:
>  /trunk/include/jal/rtc_isr_tmr3.jal
> Modified:
>  /trunk/include/jal/rtc_isr_tmr0.jal
>
> --
> You received this message because you are subscribed to the Google Groups
> "jallib" group.
> To post to this group, send email to [email protected].
> To unsubscribe from this group, send email to
> [email protected]<jallib%[email protected]>
> .
> For more options, visit this group at
> http://groups.google.com/group/jallib?hl=en.
>
>

-- 
You received this message because you are subscribed to the Google Groups 
"jallib" group.
To post to this group, send email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/jallib?hl=en.