One sensor per io line is the easy way, but that requires installing as many cables as there are sensors. It makes it difficult to add a temporary sensor at any location, using just a phone cable splitter, as I am used to do with my current network, which uses computer as a master.
On Sat, Jan 3, 2015 at 12:02 AM, Eur van Andel <[email protected]> wrote: > Hi Karlis > > I have a production version of the DS18B20 library running on 50 boards with > zero errors for the past 3 years. It does use 4 pins for 4 sensors. I have > found these sensors extremely reliable and precise. I buy watertight versions > in China in a stainless steel sleeve with 1 m wire for $1,50 a piece. Do you > want the library? I don't have write permission on jallib. -- Kārlis -- You received this message because you are subscribed to the Google Groups "jallib" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To post to this group, send email to [email protected]. Visit this group at http://groups.google.com/group/jallib. For more options, visit https://groups.google.com/d/optout.