One sensor per io line is the easy way, but that requires installing
as many cables as there are sensors. It makes it difficult to add a
temporary sensor at any location, using just a phone cable splitter,
as I am used to do with my current network, which uses computer as a
master.

On Sat, Jan 3, 2015 at 12:02 AM, Eur van Andel <[email protected]> wrote:
> Hi Karlis
>
> I have a production version of the DS18B20 library running on 50 boards with 
> zero errors for the past 3 years. It does use 4 pins for 4 sensors. I have  
> found these sensors extremely reliable and precise. I buy watertight versions 
> in China in a stainless steel sleeve with 1 m wire for $1,50 a piece. Do you 
> want the library? I don't have write permission on jallib.


-- 
Kārlis

-- 
You received this message because you are subscribed to the Google Groups 
"jallib" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send email to [email protected].
Visit this group at http://groups.google.com/group/jallib.
For more options, visit https://groups.google.com/d/optout.

Reply via email to