1) The client proxy doing automatic failover

The client proxy needs to reget the ServerIL (connection factory) from the new
singleton and reinitialise.

This could be done:
a) Simply, but as not very reliable (Use HAJNDI). The HAJNDI stub would
need regular updates of active cluster locations - which wouldn't happen unless there
are regular invocations over a HA
b) Use the HA mechanism to do JMS communication, i.e. piggy back 
changed cluster views on the back of jms invocations.