https://issues.jenkins-ci.org/browse/JENKINS-12771?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
SCM/JIRA link daemon resolved JENKINS-12771.
--------------------------------------------
Resolution: Fixed
> The init script will run multiple times rather than only the first time the
> instance is started
> -----------------------------------------------------------------------------------------------
>
> Key: JENKINS-12771
> URL: https://issues.jenkins-ci.org/browse/JENKINS-12771
> Project: Jenkins
> Issue Type: Bug
> Components: ec2
> Reporter: francis Upton
> Assignee: Kohsuke Kawaguchi
>
> The code to check for the marker file for the init script is:
> test -e /.hudson-run-init
> But the code to set the init script marker is:
> touch ~/.hudson-run-init
--