https://issues.jenkins-ci.org/browse/JENKINS-12771?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

SCM/JIRA link daemon resolved JENKINS-12771.
--------------------------------------------

    Resolution: Fixed
    
> The init script will run multiple times rather than only the first time the 
> instance is started
> -----------------------------------------------------------------------------------------------
>
>                 Key: JENKINS-12771
>                 URL: https://issues.jenkins-ci.org/browse/JENKINS-12771
>             Project: Jenkins
>          Issue Type: Bug
>          Components: ec2
>            Reporter: francis Upton
>            Assignee: Kohsuke Kawaguchi
>
> The code to check for the marker file for the init script is:
> test -e /.hudson-run-init
> But the code to set the init script marker is:
> touch ~/.hudson-run-init

--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators: 
https://issues.jenkins-ci.org/secure/ContactAdministrators!default.jspa
For more information on JIRA, see: http://www.atlassian.com/software/jira

        