Code changed in jenkins
User: Kohsuke Kawaguchi
Path:
src/main/java/hudson/remoting/ChunkedInputStream.java
http://jenkins-ci.org/commit/remoting/83da718ab06b2f881aa08434684a02ea95ff5135
Log:
[FIXED JENKINS-23471]
if readUntilBreak hits stream EOF, it would end up hanging in a busy loop. EOF is a break boundary,
so it should cause the method to return gracefully.