There seems to be a workaround that still allows Jenkins to set the Synergy workarea.
Set the Jenkins project path with forward slashes (i.e. C:/Projects/myjenkinsproject).
Jenkins then issues the command ccm attr -m wa_path -v C:/Projects/myjenkinsproject -project ....)
and the Synergy Client accept this (and translates this to a Windows Path when working on Windows).
Tested with Jenkins 1.588 and Synergy Developper (Java) Client Client 7.1.