Change By:
|
Yoann Dubreuil
(24/Feb/15 10:32 PM)
|
|
Description:
|
I find a way to trigger a remoting problem using tcp fault injection with netem. I'm able to trigger this wait call at hudson.remoting.Request.call(Request.java:146):
{
{
code}
while(response==null && !channel.isInClosed()) // I don't know exactly when this can happen, as pendingCalls are cleaned up by Channel, // but in production I've observed that in rare occasion it can block forever, even after a channel // is gone. So be defensive against that. wait(30*1000);
{code
}
}
When this wait is triggered, the running build is stuck and consumes a executor. It loops over and over on the wait.
To reproduce, setup a SSH slave using the attached Dockerfile, and setup netem on the docker0 bridge like this:
{code}
tc qdisc add dev docker0 root netem tc qdisc change dev docker0 root netem corrupt 1
{code}
Testing requires to run the job one time before configuring netem, as netem settings are applied to all network streams, it could fail while downloading Maven dependencies. I just launched a Maven build of a example project to trigger the problem. It might be a Maven specific problem...
To remove netem settings, just run tc qdisc del dev docker0 root.
I've attached the Dockerfile, the command I used to launch it and a threaddump of a Jenkins stuck master.
|
|
|
|
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators.
For more information on JIRA, see: http://www.atlassian.com/software/jira
|
--
You received this message because you are subscribed to the Google Groups "Jenkins Issues" group.
To unsubscribe from this group and stop receiving emails from it, send an email to
[email protected].
For more options, visit
https://groups.google.com/d/optout.