Oh here we go.... from the master log.. May 22, 2013 9:43:29 AM hudson.triggers.SCMTrigger$Runner run INFO: SCM changes detected in HOS251Filter-main-line. Triggering #419 May 22, 2013 9:44:08 AM hudson.model.Run execute INFO: HOS251Filter-main-line #419 main build action completed: SUCCESS May 22, 2013 9:52:31 AM hudson.TcpSlaveAgentListener$ConnectionHandler run INFO: Accepted connection #4 from /192.168.214.3:34640 May 22, 2013 9:52:31 AM jenkins.slaves.JnlpSlaveAgentProtocol$Handler error WARNING: TCP slave agent connection handler #4 with /192.168.214.3:34640 is aborted: SRV-LJS-03 is already connected to this master. Rejecting this connection. May 22, 2013 9:57:38 AM hudson.slaves.ChannelPinger$1 onDead INFO: Ping failed. Terminating the channel. java.util.concurrent.TimeoutException: Ping started on 1369212818723 hasn't completed at 1369213058726 at hudson.remoting.PingThread.ping(PingThread.java:120) at hudson.remoting.PingThread.run(PingThread.java:81) May 22, 2013 9:57:38 AM hudson.remoting.SynchronousCommandTransport$ReaderThread run SEVERE: I/O error in channel SRV-LJS-03 java.net.SocketException: Socket closed at java.net.SocketInputStream.socketRead0(Native Method) at java.net.SocketInputStream.read(SocketInputStream.java:146) at java.io.BufferedInputStream.fill(BufferedInputStream.java:235) at java.io.BufferedInputStream.read(BufferedInputStream.java:254) at java.io.ObjectInputStream$PeekInputStream.peek(ObjectInputStream.java:2290) at java.io.ObjectInputStream$BlockDataInputStream.peek(ObjectInputStream.java:2583) at java.io.ObjectInputStream$BlockDataInputStream.peekByte(ObjectInputStream.java:2593) at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1315) at java.io.ObjectInputStream.readObject(ObjectInputStream.java:369) at hudson.remoting.Command.readFrom(Command.java:92) at hudson.remoting.ClassicCommandTransport.read(ClassicCommandTransport.java:59) at hudson.remoting.SynchronousCommandTransport$ReaderThread.run(SynchronousCommandTransport.java:48) May 22, 2013 9:57:38 AM jenkins.slaves.JnlpSlaveAgentProtocol$Handler$1 onClosed WARNING: Channel reader thread: SRV-LJS-03 for + SRV-LJS-03 terminated java.net.SocketException: Socket closed at java.net.SocketInputStream.socketRead0(Native Method) at java.net.SocketInputStream.read(SocketInputStream.java:146) at java.io.BufferedInputStream.fill(BufferedInputStream.java:235) at java.io.BufferedInputStream.read(BufferedInputStream.java:254) at java.io.ObjectInputStream$PeekInputStream.peek(ObjectInputStream.java:2290) at java.io.ObjectInputStream$BlockDataInputStream.peek(ObjectInputStream.java:2583) at java.io.ObjectInputStream$BlockDataInputStream.peekByte(ObjectInputStream.java:2593) at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1315) at java.io.ObjectInputStream.readObject(ObjectInputStream.java:369) at hudson.remoting.Command.readFrom(Command.java:92) at hudson.remoting.ClassicCommandTransport.read(ClassicCommandTransport.java:59) at hudson.remoting.SynchronousCommandTransport$ReaderThread.run(SynchronousCommandTransport.java:48)
On Tuesday, 28 May 2013 15:33:53 UTC+1, Stuart Green wrote: > > Yes that's right. I'd need to reboot it again whilst watching to be > absolutely sure of what the master is thinking. Certainly it would be back > up within those 4 minutes though. > > I might have to go with something like you've made, either your approach > or maybe a massive sleep in the init script! Cheers for the reply. > > Stu > > On Tuesday, 28 May 2013 15:27:02 UTC+1, Mandeville, Rob wrote: >> >> So the server is complaining that it already has a server by that >> name. When the slave job is down, does the Server still regard it as up? >> Maybe Jenkins hasn’t noticed yet (there’s a 4-minute “ping timeout” >> involved, so it might not have). >> >> >> >> I have a cron job that runs every five minutes, looking for the slave job >> with the help of “ps”. When it can’t find it, it fires off “nohup bash >> launchSlave.sh &”. The launchSlave.sh job sets some environment variables >> and launches “java –jar slave.jar –jnlpUrl …”. >> >> >> >> --Rob >> >> >> >> *From:* [email protected] [mailto:[email protected]] >> *On Behalf Of *Stuart Green >> *Sent:* Tuesday, May 28, 2013 10:03 AM >> *To:* [email protected] >> *Subject:* Jenkins Linux Slave fails to connect to Jenkins master - JLNP >> Java Web Start >> >> >> >> Hello.. >> >> >> >> This is getting to be a bit of a pain, it seems to happen every time we >> reboot the linux slave, but does not happen when we reboot the windows >> slave that we have. We are on Jenkins ver. 1.515 so the fix in 1.398(off >> the top of my head) is definitely there. >> >> >> >> >> >> May 15, 2013 11:13:37 AM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Connected >> >> May 15, 2013 11:13:37 AM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Connected >> >> Session terminated, killing shell... ...killed. >> Skipping HTTPS certificate checks altogether. Note that this is not >> secure at all. >> May 22, 2013 9:52:30 AM hudson.remoting.jnlp.Main$CuiListener <init> >> INFO: Jenkins agent is running in headless mode. >> May 22, 2013 9:52:31 AM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Locating server among [https://jenkins.internal.ourserver.com/, >> http://jenkins.internal.ourserver.com/] >> May 22, 2013 9:52:31 AM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Connecting to jenkins.internal.ourserver.com:8081 >> May 22, 2013 9:52:31 AM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Handshaking >> May 22, 2013 9:52:31 AM hudson.remoting.jnlp.Main$CuiListener error >> SEVERE: The server rejected the connection: SRV-LJS-03 is already >> connected to this master. Rejecting this connection. >> java.lang.Exception: The server rejected the connection: SRV-LJS-03 is >> already connected to this master. Rejecting this connection. >> at hudson.remoting.Engine.onConnectionRejected(Engine.java:257) >> at hudson.remoting.Engine.run(Engine.java:232) >> >> >> >> Then if I start it manually (when someone shouts) its fine. >> Skipping HTTPS certificate checks altogether. Note that this is not >> secure at all. >> May 28, 2013 2:17:10 PM hudson.remoting.jnlp.Main$CuiListener <init> >> INFO: Jenkins agent is running in headless mode. >> May 28, 2013 2:17:10 PM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Locating server among [https://jenkins.internal.ourserver.com/, >> http://jenkins.internal.ourserver.com/] >> May 28, 2013 2:17:10 PM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Connecting to jenkins.internal.ourserver.com:8081 >> May 28, 2013 2:17:10 PM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Handshaking >> May 28, 2013 2:17:10 PM hudson.remoting.jnlp.Main$CuiListener status >> INFO: Connected >> >> >> >> >> >> Is there anyone that is using the same method sucessfully able to advise >> on how they are doing it? >> >> >> >> Thanks, >> >> Stu >> >> -- >> You received this message because you are subscribed to the Google Groups >> "Jenkins Users" group. >> To unsubscribe from this group and stop receiving emails from it, send an >> email to [email protected]. >> For more options, visit https://groups.google.com/groups/opt_out. >> >> >> The information in this message is for the intended recipient(s) only >> and may be the proprietary and/or confidential property of Litle & Co., >> LLC, and thus protected from disclosure. If you are not the intended >> recipient(s), or an employee or agent responsible for delivering this >> message to the intended recipient, you are hereby notified that any use, >> dissemination, distribution or copying of this communication is prohibited. >> If you have received this communication in error, please notify Litle & Co. >> immediately by replying to this message and then promptly deleting it and >> your reply permanently from your computer. >> > -- You received this message because you are subscribed to the Google Groups "Jenkins Users" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. For more options, visit https://groups.google.com/groups/opt_out.