A little more information: here is how the AbstractCloudSlave._terminate()
method is implemented in my custom slave:
@Override
protected void _terminate(TaskListener listener) throws IOException,
InterruptedException {
LOGGER.log(Level.INFO, "Terminating Kubernetes instance for slave
{0}", name);
try {
cloud.client().deletePod(name, KubernetesCloud.POD_NAMESPACE);
LOGGER.log(Level.INFO, "Terminated Kubernetes instance for
slave {0}", name);
toComputer().disconnect(null);
} catch (Exception e) {
LOGGER.log(Level.SEVERE, "Failure to terminate instance for
slave " + name, e);
}
}
I'm wondering if the toComputer().disconnect(null) is appropriate.
On Saturday, July 18, 2015 at 6:38:22 PM UTC-7, Mark Petrovic wrote:
>
> I am developing a cloud plugin that spins up nodes on demand to build
> projects inside Docker containers.
>
> Everything is worked well, but I see these exceptions in the log when a
> node finishes its job and I _terminate it:
>
> Jul 18, 2015 5:41:21 PM hudson.model.Run execute
> INFO: boot-continuous-develop #15 main build action completed: SUCCESS
> Jul 18, 2015 5:41:21 PM com.xoom.inf.jenkins.plugins.KubernetesSlave
> _terminate
> INFO: Terminating Kubernetes instance for slave
> 25cf5bd9-1bb8-468a-bca3-faeba0a84bde
> Jul 18, 2015 5:41:22 PM com.xoom.inf.jenkins.plugins.KubernetesSlave
> _terminate
> INFO: Terminated Kubernetes instance for slave
> 25cf5bd9-1bb8-468a-bca3-faeba0a84bde
> Jul 18, 2015 5:41:22 PM
> hudson.remoting.AbstractByteArrayCommandTransport$1 handle
> WARNING: Failed to construct Command
> java.io.EOFException
> at
> java.io.ObjectInputStream$PeekInputStream.readFully(ObjectInputStream.java:2328)
> at
> java.io.ObjectInputStream$BlockDataInputStream.readShort(ObjectInputStream.java:2797)
> at
> java.io.ObjectInputStream.readStreamHeader(ObjectInputStream.java:802)
> at java.io.ObjectInputStream.<init>(ObjectInputStream.java:299)
> at
> hudson.remoting.ObjectInputStreamEx.<init>(ObjectInputStreamEx.java:40)
> at
> hudson.remoting.AbstractByteArrayCommandTransport$1.handle(AbstractByteArrayCommandTransport.java:61)
> at
> org.jenkinsci.remoting.nio.NioChannelHub$2.run(NioChannelHub.java:594)
> at
> java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511)
> at java.util.concurrent.FutureTask.run(FutureTask.java:266)
> at
> hudson.remoting.SingleLaneExecutorService$1.run(SingleLaneExecutorService.java:112)
> at
> jenkins.util.ContextResettingExecutorService$1.run(ContextResettingExecutorService.java:28)
> at
> java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:511)
> at java.util.concurrent.FutureTask.run(FutureTask.java:266)
> at
> java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1142)
> at
> java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:617)
> at java.lang.Thread.run(Thread.java:745)
>
>
> What does this mean and how can I prevent this?
>
> Thank you.
>
>
--
You received this message because you are subscribed to the Google Groups
"Jenkins Users" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion on the web visit
https://groups.google.com/d/msgid/jenkinsci-users/fb5af5c0-dc6e-46c5-80e0-9776f7085b3e%40googlegroups.com.