Hi

 

For ciscos I still can’t add the controllers. When I set it to autodiscovery, I see this in the log:

“05:30:05 I40 : ==========================================================================================

05:30:05 I40 : Start: 2005-04-08 04:55:00       Stop: 2005-04-08 05:25:00       Measures: 6

05:30:05 I40 : cpu(8) mem_used(84750999) mem_free(405150133) acct_packets(0) acct_bytes(0) tcp_active(0) tcp_passive(0) tcp_established(0)

05:30:05 I40 : ------------------------------------------------------------------------------------------

05:30:05 I40 : sla : Cond0: (8 > 60)                               = 0  -FALSE- CPU > 60%: 8 %

05:30:05 I40 : sla : Cond1: ( ((84750999 * 100) / (84750999 + 405150133)) > 80) = 0  -FALSE- Memory Usage > 80%: 17.3 %

05:30:05 I40 : sla : Cond0= Eval 1 vs 0: 0 OR 0                    = 0

05:30:05 I40 : sla : Final Eval: False.

05:30:06 H   9 : IT   4 : Autodiscovering Physical Interfaces

05:30:07  :  H   3 : Poller Start : 0 Items.

05:30:07  :  H   3 : Poller End, Total Time: 7.66 msec.

05:30:07  :  H   3 : Poller Start : 0 Items.

05:30:07  :  H   3 : Poller End, Total Time: 35.55 msec.

05:30:07 Launcher Starting. Parameters: childs: 5, Timeout: 480, item Retries: 1, Rest Time: 3 secs, Read Timeout: 3, Child Hearbeat every 5 secs.

05:30:07 ITEMS     Added 1 items”

 

 

 

“05:30:44 H   9 : IT   4 : I 1787 : RES : Nothing Done.

05:30:44 H   9 : IT   4 : I 1788 : DB  : Not Found

05:30:44 H   9 : IT   4 : I 1788 : HOST: inte: Serial7/0:24:0 | desc:  | addr:  | mask:  | peer:  | band: 64000 | band: 64000 | perc:  | ping:

05:30:44 H   9 : IT   4 : I 1788 : RES : Nothing Done.

05:30:44 H   9 : IT   4 : I 1789 : DB  : Not Found

05:30:44 H   9 : IT   4 : I 1789 : HOST: inte: Serial7/0:24:1 | desc:  | addr:  | mask:  | peer:  | band: 64000 | band: 64000 | perc:  | ping:”

 

For the ones added to monitoring, the log are like:

“05:30:45 H   9 : IT  16 : Autodiscovering Cisco Power Supply

05:30:45 H   9 : IT  16 : I    1 : DB  : inte: PowerSupply1 | desc: Redundant Power Supply

05:30:45 H   9 : IT  16 : I    1 : HOST: inte: PowerSupply1 | desc: Redundant Power Supply

05:30:45 H   9 : IT  16 : I    1 : RES : Nothing Done.

05:30:45 H   9 : IT  17 : Autodiscovering Cisco Temperature

05:30:45 H   9 : IT  17 : I    1 : DB  : inte: Temperature1 | desc: maximum temperature in chassis

05:30:45 H   9 : IT  17 : I    1 : HOST: inte: Temperature1 | desc: maximum temperature in chassis

05:30:45 H   9 : IT  17 : I    1 : RES : Nothing Done.”

 

Why is this happening?

Thx

........................................................................

ALEXANDRU BADULESCU

Switching Engineer

NOBEL Ltd.

Phone: +1 888 896 6235

International number: 1 619 387 7679

[EMAIL PROTECTED]

 

We re available 24/7

This e-mail and attachments, if any, may contain confidential and/or proprietary information. Please be advised that the unauthorized use or disclosure of the information is strictly prohibited. The information herein is intended only for use by the intended recipient(s) named above. If you have received this transmission in error, please notify the sender immediately and permanently delete the e-mail and any copies, printouts or attachments thereof.

.................................................................

 

Reply via email to