Hi,

Thank you Graig for your answer.
I've found my problem, it was the type of the rrd value. I didn't know 
that a rrd counter value was calculated like that : counter = 
counter(t)-counter(t-d)/d. So I have defined my value as a gauge one and 
it works. But to make it works I advise to use rrdtool to check the rrd 
files.

-------------------------------------------------------------------------