Hi Jordi
 
Thank you very much. Here is one more small doubt.
In this situation if I use Constant Throughput Timer (20sec) instead of Constant 
Timer(20sec) and if the response time of the HTTP Sampler1 is more than 20sec (Timer 
value) say 30 sec, When will the HTTP Sampler will be started? Is it at 10.30.25 A.M. 
(by considering only Constant Throughput Timer value) or any other time?
 
Regards
Eda


Jordi Salvat i Alabart <[EMAIL PROTECTED]> wrote:
10.30.35 A.M.

Constant Timer introduces a constant delay before each sampler.

To make it be 1.30.25, you should use the Constant Throughput Timer, 
which introduces a variable delay so that the rate at which samplers 
occur remains constant.

-- 
Salut,

Jordi.

Eda Srinivasareddy wrote:
> Hi All
> 
> My Thread Group contains the following elements
> 
> Constant Timer (20seconds at Thread Group level)
> HTTP Sampler1
> HTTP Sampler2
> 
> Lets think that the execution of HTTP Sampler1 started at 10:30:05 A.M. for a user. 
> If the response time for HTTP Smapler1 is 10seconds, when will the execution of the 
> HTTP Sampler2 start? Is it at 10.30.35 A.M.(response time(10) + constant timer 
> time(20)) or 10.30.25 A.M.(only constant timer time(20))? 
> 
> Thank you very much for your help.
> 
> Regards
> Eda
> 
> 
> ---------------------------------
> Do you Yahoo!?
> Yahoo! Finance: Get your refund fast by filing online

---------------------------------------------------------------------
To unsubscribe, e-mail: [EMAIL PROTECTED]
For additional commands, e-mail: [EMAIL PROTECTED]


---------------------------------
Do you Yahoo!?
Yahoo! Finance: Get your refund fast by filing online

Reply via email to