Bob,

whatever magic you did - it fixed the atom duplication.
However, I think the unit cell should have only 9 atoms, not 10.



The Mg atom (0.0  0.0  17.59) pointed to by the arrow should be in the next cell, shouldn't it?.

I'm afraid that I did not catch the meaning of what I should do about "REMARK 290".

Anyhow, thank you very much for this incredibly fast turn around.

Are you going to release your fix soon?

Greets,
Hans

On 11/29/2011 8:09 PM, Robert Hanson wrote:
Hans,

OK, I got it. Very simple fix. See http://chemapps.stolaf.edu/jmol/docs/examples-12/Jmol-12.zip

By the way, Jmol is guessing at the origin and setting of that unit cell. Jmol can read the Jones-Faithful data in the PDB record REMARK 290:

REMARK 290 CRYSTALLOGRAPHIC SYMMETRY                                           
REMARK 290 SYMMETRY OPERATORS FOR SPACE GROUP: P 1 21 1                        
REMARK 290                                                                     
REMARK 290      SYMOP   SYMMETRY                                               
REMARK 290     NNNMMM   OPERATOR                                               
REMARK 290       1555   X,Y,Z                                                  
REMARK 290       2555   -X,Y+1/2,-Z                                            
REMARK 290                                                                     

That's guaranteed to work.

Bob Hanson

------------------------------------------------------------------------------