We were having the same problem, we found a very good article that helped us 
to solve the problem, check it out, I hope it helps:

http://www.macromedia.com/devnet/server_archive/articles/performance_tuning_jrun31.html

Juan

>From: Ben Groeneveld <[EMAIL PROTECTED]>
>Reply-To: [EMAIL PROTECTED]
>To: JRun-Talk <[EMAIL PROTECTED]>
>Subject: High Traffic JRun4 Settings
>Date: Wed, 20 Aug 2003 18:07:20 -0700
>
>JRun fans, I am experimenting with high volume settings for JRun under
>IIS.  I seem to bump up against a limit of 1000 user threads open.  I
>have configured the default server SERVER-INF/jrun.xml as follows:
>
>   <service class="jrun.servlet.jrpp.JRunProxyService" name="ProxyService">
>     <!--<attribute name="activeHandlerThreads">25</attribute>-->
>     <attribute name="activeHandlerThreads">1005</attribute>
>     <attribute name="backlog">500</attribute>
>     <attribute name="deactivated">false</attribute>
>     <attribute name="interface">*</attribute>
>     <!--<attribute name="maxHandlerThreads">1000</attribute>-->
>     <attribute name="maxHandlerThreads">1005</attribute>
>     <attribute name="minHandlerThreads">1</attribute>
>     <attribute name="port">51000</attribute>
>     <attribute name="threadWaitTimeout">20</attribute>
>     <attribute name="timeout">300</attribute>
>
>At 1000 concurrent connections the jrun server will start complaining
>that I need to configure it for more threads.  I can set the active and
>or max handler threads higher, e.g., 2000, and it has no effect.  When I
>experimented with low numbers, these params normally allow me (N-1)
>concurrent connections, where N is the HandlerThread param.  Now from
>what I understand, each socket connection will hold onto one thread, and
>a VM on NT should be able to handle 2048 threads or so.  Anyone have any
>idea what I am missing?
>
>I don't think IIS is the issue.  But for what it's worth, I have JRun
>connected to IIS5 on win2k server, which is configured to as follows:
>
>100,000 hits per day
>ListenBackLog 500
>AcceptExOutstanding 200
>MaxPoolThreads 20
>PoolThreadLimit 2000
>ServerListenBackLog 2000
>MaxEndPointConnections 2000
>
>Thanks for any advice.  BenG.
>
>--
>Ben Groeneveld
>Information Concepts, Inc., 115 N.W. Oregon, Suite 30, Bend, OR 97701
>Mailto:[EMAIL PROTECTED], phone:541.388.3611, cell:541.420.6246
>
>
>
>
>
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~|
Archives: http://www.houseoffusion.com/lists.cfm?link=t:8
Subscription: http://www.houseoffusion.com/lists.cfm?link=s:8
Unsubscribe: 
http://www.houseoffusion.com/cf_lists/unsubscribe.cfm?user=<:emailid:>.<:userid:>.<:listid:>

Your ad could be here. Monies from ads go to support these lists and provide more 
resources for the community. 
http://www.fusionauthority.com/ads.cfm

                        

Reply via email to