Chris Morrow wrote: > > > On Wed, 23 May 2007, TCIS List Acct wrote: > >> First, thanks to everyone that responded to my questions yesterday -- >> I think we >> have decided on going the new M7i route. >> >> Now, on to the next question -- we plan to use NetFlow for billing >> purposes, and >> I've read that Juniper's NetFlow is limited to 7,000pps or something >> similar. > > 7kpps for RE sampled traffic, and it's 7k samples/second. So if you > sample 1:100 it's really 700kpps. Make sense? The M7i comes with an > integrated AS-PIC, the AS-PIC will do many things one of which is > 'sampling' :) It does this at about 400kpps samples, so 1:100 sampling > means you can sample about 40,000kpps (40mpps). >
Do all M7i's come with an integrated AS-PIC? I thought that was only included on the -ASM model? I assume with 1:100 sampling, that means that I am missing flows? --Mike _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp