On Tue, Dec 04, 2007 at 11:48:12AM -0500, Stefan Fouant wrote:
> CFlowD requires the use of either an AS1-PIC or AS2-PIC (I believe they are
> now EOS), or an MS-PIC which generate the CFlowD v5 and v8 records and
> export them to an external CFlowD collector. Since olives don't have this
> hardware they will be unable to perform this function.
This is incorrect, you can run "RE based" export on m20/m40
and other devices where the PFE punts the bits to sampled on the
RE.
Performance may not be the best, you may lose data, etc..
but it works.
- Jared
--
Jared Mauch | pgp key available via finger from [EMAIL PROTECTED]
clue++; | http://puck.nether.net/~jared/ My statements are only mine.
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp