This may not be the case in your scenario, but I once found that I had the appearance of the physical layer being down between an M7i and a switch after having configured vlan-tagging on an aggregated Ethernet link. This strangely persisted until I had mapped a VLAN on both ends (i.e., configured some sort of unit in the Juniper with a VLAN tag that actually corresponded to a VLAN whose frames were being passed to the aggregated Ethernet link by the switch). Coincidentally, it was a PE-4FE-TX in my case as well.
HTH, -FC On Jan 28, 2008 5:17 PM, John T. Yocum <[EMAIL PROTECTED]> wrote: > Hello, > > Got a strange problem. I'm trying to setup an aggregated ethernet > connection between a PE-4FE-TX and an Extreme BD6808 with F48Ti. > > I've tried both both straight through and cross-over cables but I can't > get a link-light on either side. As well, neither of them log an event > of a connection error. > > Anyone else had any trouble getting them to connect, or have any advice? > And, yes I did check, the ports are enabled on both sides. > > Thanks, > John > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp > _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp