Nope you can do flow export without the Monitoring/AS/MS-PICs but
you'll probably want to drop that sampling rate down pretty low... say
1:500 or 1:1000 in order to reduce the performance impact; without
these pics the sampling and flow export is done on the RE.



On 7/19/08, Samit <[EMAIL PROTECTED]> wrote:
> Hi list,
>
> Like in Cisco router, in order to export flows from Juniper router to
> external flow collector/analyzer and visualizer, does the adaptive
> service pic or monitoring service pic is required compulsory?
>
> Regards,
> Samit
>
> _______________________________________________
> juniper-nsp mailing list [email protected]
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>

-- 
Sent from Gmail for mobile | mobile.google.com

Stefan Fouant
Principal Network Engineer
NeuStar, Inc. - http://www.neustar.biz
GPG Key ID: 0xB5E3803D
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp