Hi

I have a case about this issue it should be fixed in the next version 9.3R4
9.4R3 9.5R2

Nitzan


On Tue, Jun 9, 2009 at 15:48, Bjørn Tore <[email protected]> wrote:

> We are trying out some EX 4200 switches running 9.5R1.8. Anyone managed to
> actually lock the port to 1000Fdx? Seems that this is a feature yet to be
> implemented. Auto/auto works fine.
> If I do
>        ether-options {
>            no-auto-negotiation;
>            no-flow-control;
>            link-mode full-duplex;
>            speed {
>                1g;
>            }
>        }
>    }
> I get link one way (on the other non-Juniper switch) because it will link
> on incoming light. The EX does not.
> Anyone tried this?
>
> Bjørn Tore
> _______________________________________________
> juniper-nsp mailing list [email protected]
> https://puck.nether.net/mailman/listinfo/juniper-nsp
>
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to