Hi The problem is not in the booting phase, but it's during switchover process. The alarm is cleared when taking the corresponding fabric plane offline then online.
Best Regards, Walaa Abdel Razzak Senior Networks Engineer JNCIP-M Tel : +966147907 Fax: +96614790878 GSM : +966594366310 -----Original Message----- From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Tuesday, July 28, 2009 8:41 PM To: [email protected] Subject: [j-nsp] MX960 SCB Alarm Hi I have experienced your issue ever. I guess you might meet this PR. NUMBER 408359 SEVERITY minor PRIORITY medium CATEGORY sw STATE closed SYNOPSIS MX SCB may fail to online at boot up sequence RELEASE 8.5R3.4; 9.3R1.7; 9.3R2.3; 9.3-20081208 COMMITTED-IN RELEASE 8.5R5; 9.3R3; 9.4R2 ARRIVAL DATE 2008-12-10 06:05:52 LAST MODIFIED 2009-05-08 14:45:20 CLOSE DATE 2009-03-03 20:38:48 RELEASE NOTE When you configure graceful Routing Engine switchover (GRES) on MX-series routers, the Switch Interface Board (SIB) might not initialize if you reboot both Routing Engines simultaneously or reboot a router with only one Routing Engine installed. This describes the boot sequesce of each RE. kazuhiro _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp __________ Information from ESET Smart Security, version of virus signature database 4223 (20090708) __________ The message was checked by ESET Smart Security. http://www.eset.com __________ Information from ESET Smart Security, version of virus signature database 4223 (20090708) __________ The message was checked by ESET Smart Security. http://www.eset.com _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp