Hi

The problem is not in the booting phase, but it's during switchover process. 
The alarm is cleared when taking the corresponding fabric plane offline then 
online.

Best Regards,
Walaa Abdel Razzak
Senior Networks Engineer 
JNCIP-M

Tel : +966147907
Fax:  +96614790878
GSM : +966594366310



-----Original Message-----
From: [email protected] 
[mailto:[email protected]] On Behalf Of 
[email protected]
Sent: Tuesday, July 28, 2009 8:41 PM
To: [email protected]
Subject: [j-nsp] MX960 SCB Alarm

Hi

I have experienced your issue ever.
I guess you might meet this PR.

NUMBER 408359 
SEVERITY minor 
PRIORITY medium 
CATEGORY sw  
STATE closed  
SYNOPSIS MX SCB may fail to online at boot up sequence  
RELEASE 8.5R3.4; 9.3R1.7; 9.3R2.3; 9.3-20081208  
COMMITTED-IN RELEASE 8.5R5; 9.3R3; 9.4R2  
ARRIVAL DATE 2008-12-10 06:05:52  
LAST MODIFIED 2009-05-08 14:45:20  
CLOSE DATE 2009-03-03 20:38:48  
RELEASE NOTE When you configure graceful Routing Engine switchover (GRES) on 
MX-series routers, the Switch Interface Board (SIB) might not initialize if you 
reboot both Routing Engines simultaneously or reboot a router with only one 
Routing Engine installed.

This describes the boot sequesce of each RE.

kazuhiro
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp
 

__________ Information from ESET Smart Security, version of virus signature 
database 4223 (20090708) __________

The message was checked by ESET Smart Security.

http://www.eset.com
 
 

__________ Information from ESET Smart Security, version of virus signature 
database 4223 (20090708) __________

The message was checked by ESET Smart Security.

http://www.eset.com
 
_______________________________________________
juniper-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/juniper-nsp

Reply via email to