> -----Original Message-----
> From: [email protected] [mailto:juniper-nsp-
> [email protected]] On Behalf Of Alex
> Sent: Saturday, November 28, 2009 8:05 AM
> 
> This is correct fxp0 behaviour.
> Just pick any other PFE interface for outband access and put it into
> routing-instance.
> In this fashion, with dedicated OOB PFE interface, if your M7i RE
> fails, you
> still have OOB access to the node.

If the RE fails, what would you be logging into?  There would be nothing
else running mgd.